Exact charge industries Call Us Toll Free At 1-866-717-9937
Instruction Manual
 
INSTRUCTION TO PERFORM SUPERHEAT/SUBCOOLING,DUCT SIZING AND PRESSURE SETTINGS
SUPERHEAT FUNCTION
1. PRESS WET BULB KEY
    Enter wet bulb reading on 0-9 keypad
 
2. PRESS DRY BULB KEY
    Enter indoor dry bulb reading on 0-9 keypad
 
3. PRESS OUTDOOR AMBIENT KEY KEY
    Enter outdoor ambient temperature on 0-9 keypad
 
4. PRESS SUPERHEAT KEY
    Readout displays targeted superheat in degrees Fahrenheit
 
1. PRESS REFRIGERANT KEY
    Enter 3 digit # followed by A, B, or C (if needed) on 0-9 keypad
 
2. PRESS SUPERHEAT KEY
    Enter targeted superheat on 0-9 keypad or desired superheat value
 
3. PRESS PRESSURE KEY
    Enter suction line pressure reading on 0-9 keypad
 
4. PRESS LINE TEMPERATURE KEY
    Readout displays required suction line temperature in degrees Fahrenheit
 
    Add or Substract refrigerent charge if required
 
SUBCOOLING FUNCTION
 
1. PRESS REFRIGERANT KEY
    Enter refrigerant # followed by A, B, or C (if needed) on 0-9 keypad
 
2. PRESS SUBCOOLING KEY
    Enter required subcooling on 0-9 keypad
 
3. PRESS PRESSURE KEY
    Enter liquid line pressure reading on 0-9 keypad
 
4. PRESS LINE TEMPERATURE KEY
    LCD displays required liquid line temperature in degrees Fahrenheit Adjust refrigerant charge      if required
 
ACTUAL SYSTEM SUBCOOLING FUNCTION
 
1. PRESS REFRIGERANT KEY
    Enter refrigerant # followed by A, B, or C (if needed) on 0-9 key pad
 
2. PRESS PRESSURE KEY
    Enter high side pressure reading on 0-9 key pad
 
3. PRESS LINE TEMPERATURE KEY
    Enter liquid line temperature on 0-9 key pad
 
4. PRESS SUBCOOLING KEY
    LCD displays actual subcooling in degrees Fahrenheit Adjust refrigerant charge if required
 
ACTUAL SYSTEM SUPERHEAT FUNCTION
 
1. PRESS REFRIGERANT KEY
    Enter refrigerant # followed by A, B, or C (if needed) on 0-9 key pad
 
2. PRESS PRESSURE KEY
    Enter low side pressure reading on 0-9 key pad
 
3. PRESS LINE TEMPERATURE KEY
    Enter suction line temperature reading on 0-9 reading
 
4. PRESS SUPERHEAT KEY
    LCD displays actual system superheat in degrees Fahrenheit Adjust refrigerant charge if     required
 
PRESSURE TEMPERATURE RELATIONSHIP
 
1. PRESS REFRIGERANT KEY
    Enter refrigerant # followed by A, B, or C (if needed) on 0-9 keypad
 
2. PRESS PRESSURE KEY
    Enter pressure reading on 0-9 keypad
 
3. PRESS TEMPERATURE KEY
    LCD displays temperature in degrees Fahrenheit
 
TEMPERATURE PRESSURE RELATIONSHIP
 
1. PRESS REFRIGERANT KEY
    Enter refrigerant # followed by A, B, or C (if needed) on 0-9 keypad
 
2. PRESS TEMPERATURE KEY
    Enter temperature reading on 0-9 keypad
 
3. PRESS PRESSURE KEY
    LCD displays pressure in PSIG
 
View Details
 
DUCT SIZING
 
1.PRESS CUBIC FEET PER MINUTE KEY
    Enter cubic feet per minute on 0-9 keypad
 
2. PRESS VELOCITY KEY
    Enter velocity on 0-9 keypad
 
4. PRESS ROUND DUCT KEY
    LCD displays required round duct size
 
5. PRESS RECTANGULAR DUCT KEY
    LCD displays required rectangular duct size
 
6. PRESS EQUIVALENT KEY
LCD displays equivalent rectangular duct size, Continuing to press equivalent key will display Other equivalent duct sizes until completed then Not Found is displayed on LCD
 
7. PRESS FLEX DUCT KEY
    LCD displays required flex duct size
 
8. PRESS STATIC KEY
    LCD displays corresponding static for round, rectangular, or flex duct
 
TO ATTAIN STATIC FROM CUBIC FEET PER MINUTE AND DUCT SIZE
 
1. PRESS STATIC KEY
    Enter cubic feet per minute on 0-9 keypad
 
2. PRESS STATIC KEY
 
PRESS ROUND, RECTANGULAR, OR FLEX DUCT KEYS
 
Enter duct size on 0-9 keypad Note:
For rectangular duct size enter length x width Using 0-9 keypad and multiply key
 
3. PRESS STATIC KEY
    LCD displays corresponding static
 
View Details
 
APPROXIMATE PRESSURE CONTROL SETTINGS FUNCTION
 
1. PRESS REFRIGERANT KEY
    Enter refrigerant # followed by A, B, or C (if needed) on 0-9 keypad
 
2. PRESS TEMPERATURE KEY
    Enter maximum temperature desired on 0-9 keypad
 
3. PRESS IN KEY
    LCD displays approximate pressure cut in setting
 
4. PRESS OUT KEY
    LCD displays approximate pressure cut out setting
 
View Details
 
LIST OF REFRIGERANTS
R409A R13
R414B R23
R416A R503
R404A R508B
R507 R403B
R502 R22
R402A R407C
R402B R417A
R408A R410A
R11 R12
R113 R134A
R123 R401A
R124 R401B
R500 R114
 
Disclaimer Privacy Policy User Agreement Login    
Menu Screen Superheat/Subcooling Duct Sizing Pressure Settings Diagnostic Assistant Screen Instruction Manual